Wednesday, May 13, 2015

Change Exadata Write-Back Flash cache in Rolling Mode.

---Make sure you have both of this files into one directory.

 [root@dummyCNadm01 ~]# pwd  
 /root  
 rwxr--r-- 1 root root 141286 May 12 13:47 setWBFC.sh  
 -rwxr-xr-x 1 root root  683 May 12 13:47 wbfc_FLUSH.sh  

----From compute Node. Run Pre-check to see if cell servers are ready to flip over WBFC .

 [root@dummyCNadm01 ~]# ./setWBFC.sh -g cell_group -l /tmp -m WriteBack -o rolling -p  
 ./setWBFC.sh: Using log directory '/tmp'  
 ./setWBFC.sh: Log File '/tmp/setWBFC_85166_2015-05-12-13:50:03.log' created successfully  
 2015-05-12 13:50:03  
 Starting ./setWBFC.sh on dummyCNadm01  
 Version: 1.0.0.1.6.20140716  
 Command line options used:  
  -g cell_group  
  -o rolling  
  -m WriteBack  
  -p (Perform pre-req checks only)  
  -t 21600  
  -x 0  
 2015-05-12 13:50:03  
 Performing pre-req checks.....  
 2015-05-12 13:50:03  
 Creating baseline inventory for griddisks  
 2015-05-12 13:50:06  
 Creating baseline inventory for flashdisks  
 2015-05-12 13:50:08  
 Creating baseline inventory for flashsize  
 2015-05-12 13:50:10  
 dcli present and in PATH.            [PASSED]  
 2015-05-12 13:50:10  
 Checking cell nodes are valid storage servers...  
 2015-05-12 13:50:10  
 All cells are valid Exadata storage cells.  
 2015-05-12 13:50:10  
 Checking Exadata Storage Software Versions...  
 2015-05-12 13:50:15  
 Software versions of the following cells:  
 dummy01celadm01: 12.1.2.1.1.150316.2           [PASSED]  
 dummy01celadm02: 12.1.2.1.1.150316.2           [PASSED]  
 dummy01celadm03: 12.1.2.1.1.150316.2           [PASSED]  
 dummy01celadm04: 12.1.2.1.1.150316.2           [PASSED]  
 dummy01celadm05: 12.1.2.1.1.150316.2           [PASSED]  
 dummy01celadm06: 12.1.2.1.1.150316.2           [PASSED]  
 dummy01celadm07: 12.1.2.1.1.150316.2           [PASSED]  
 2015-05-12 13:50:15  
 Checking Grid Infrastructure Software Version...  
 2015-05-12 13:50:17  
 Grid Infrastructure version: 12.1.0.2.00     [PASSED]  
 2015-05-12 13:50:17  
 Checking for active ASM operations....  
 2015-05-12 13:50:18  
 Check for no active ASM operations:       [PASSED]  
 2015-05-12 13:50:18  
 Checking griddisk status across all cells....  
 2015-05-12 13:50:20  
 All griddisks across all cells have asmdeactivationoutcome = Yes  
 All griddisks across all cells are ONLINE  
 Griddisk checks:                 [PASSED]  
 2015-05-12 13:50:20  
 Checking flash cache status.....  
 2015-05-12 13:50:21  
 Flashcache status normal:            [PASSED]  
 2015-05-12 13:50:21  
 Checking that all FlashDisks are present...  
 2015-05-12 13:50:22  
 FlashDisk validation:              [PASSED]  
 2015-05-12 13:50:22  
 Checking current flash cache mode.....  
 2015-05-12 13:50:23  
 Flashcache not already in target mode:      [PASSED]  
 2015-05-12 13:50:23  
 All pre-req checks completed:          [PASSED]  
 2015-05-12 13:50:24  
 dummy01celadm01: flashcache size: 5.82122802734375T  
 dummy01celadm02: flashcache size: 5.82122802734375T  
 dummy01celadm03: flashcache size: 5.82122802734375T  
 dummy01celadm04: flashcache size: 5.82122802734375T  
 dummy01celadm05: flashcache size: 5.82122802734375T  
 dummy01celadm06: flashcache size: 5.82122802734375T  
 dummy01celadm07: flashcache size: 5.82122802734375T  
 There are 7 storage cells to process.  

---- Turn write back ON in rolling fashion .

 [root@dummyCNadm01 ~]# ./setWBFC.sh -g cell_group -l /tmp -m WriteBack -o rolling  
 2015-05-12 14:59:41  
 Starting ./setWBFC.sh on dummy01dbadm01  
 Version: 1.0.0.1.6.20140716  
 Command line options used:  
  -g cell_group  
  -o rolling  
  -m WriteBack  
  -t 21600  
  -x 0  
 2015-05-12 14:59:41  
 Performing pre-req checks.....  
 2015-05-12 14:59:41  
 Creating baseline inventory for griddisks  
 2015-05-12 14:59:42  
 Creating baseline inventory for flashdisks  
 2015-05-12 14:59:43  
 Creating baseline inventory for flashsize  
 2015-05-12 14:59:44  
 dcli present and in PATH.            [PASSED]  
 2015-05-12 14:59:44  
 Checking cell nodes are valid storage servers...  
 2015-05-12 14:59:44  
 All cells are valid Exadata storage cells.  
 2015-05-12 14:59:44  
 Checking Exadata Storage Software Versions...  
 2015-05-12 14:59:48  
 Software versions of the following cells:  
 dummy01celadm01: 12.1.2.1.1.150316.2           [PASSED]  
 dummy01celadm02: 12.1.2.1.1.150316.2           [PASSED]  
 dummy01celadm03: 12.1.2.1.1.150316.2           [PASSED]  
 dummy01celadm04: 12.1.2.1.1.150316.2           [PASSED]  
 dummy01celadm05: 12.1.2.1.1.150316.2           [PASSED]  
 dummy01celadm06: 12.1.2.1.1.150316.2           [PASSED]  
 dummy01celadm07: 12.1.2.1.1.150316.2           [PASSED]  
 2015-05-12 14:59:48  
 Checking Grid Infrastructure Software Version...  
 2015-05-12 14:59:51  
 Grid Infrastructure version: 12.1.0.2.00     [PASSED]  
 2015-05-12 14:59:51  
 Checking for active ASM operations....  
 2015-05-12 14:59:51  
 Check for no active ASM operations:       [PASSED]  
 2015-05-12 14:59:51  
 Checking griddisk status across all cells....  
 2015-05-12 14:59:54  
 All griddisks across all cells have asmdeactivationoutcome = Yes  
 All griddisks across all cells are ONLINE  
 Griddisk checks:                 [PASSED]  
 2015-05-12 14:59:54  
 Checking flash cache status.....  
 2015-05-12 14:59:55  
 Flashcache status normal:            [PASSED]  
 2015-05-12 14:59:55  
 Checking that all FlashDisks are present...  
 2015-05-12 14:59:57  
 FlashDisk validation:              [PASSED]  
 2015-05-12 14:59:57  
 Checking current flash cache mode.....  
 2015-05-12 14:59:58  
 Flashcache not already in target mode:      [PASSED]  
 2015-05-12 14:59:58  
 All pre-req checks completed:          [PASSED]  
 2015-05-12 14:59:59  
 dummy01celadm01: flashcache size: 5.82122802734375T  
 dummy01celadm02: flashcache size: 5.82122802734375T  
 dummy01celadm03: flashcache size: 5.82122802734375T  
 dummy01celadm04: flashcache size: 5.82122802734375T  
 dummy01celadm05: flashcache size: 5.82122802734375T  
 dummy01celadm06: flashcache size: 5.82122802734375T  
 dummy01celadm07: flashcache size: 5.82122802734375T  
 There are 7 storage cells to process.  
 2015-05-12 14:59:59  
 Changing flash cache to WriteBack ROLLING....  
 2015-05-12 14:59:59  
 STEP 0: Checking gridisk status on cell: dummy01celadm01  
 2015-05-12 15:00:01  
 STEP 0 completed successfully on cell: dummy01celadm01  
 2015-05-12 15:00:04  
 STEP 1: Dropping flashcache on cell: dummy01celadm01  
 2015-05-12 15:00:36  
 STEP 1: Completed sucessfully on cell: dummy01celadm01  
 2015-05-12 15:00:39  
 Skipping STEP 2: Inactivating grid disks not required.  
 2015-05-12 15:00:39  
 Skipping STEP 3: Shutdown of cellsrv not required.  
 2015-05-12 15:00:39  
 STEP 4: Set the flashCachMode on cell: dummy01celadm01  
 2015-05-12 15:00:39  
 STEP 4: Setting flashCacheMode to WriteBack  
 2015-05-12 15:00:40  
 STEP 4: Completed successfully on cell: dummy01celadm01  
 2015-05-12 15:00:43  
 Skipping STEP 5: Restart of cellsrv not required.  
 2015-05-12 15:00:43  
 Skipping STEP 6: Acativating grid disks not required.  
 2015-05-12 15:00:43  
 STEP 7: Creating flashcache on cell: dummy01celadm01  
 2015-05-12 15:01:32  
 STEP 7: Completed sucessfully on cell: dummy01celadm01  
 2015-05-12 15:01:35  
 STEP 8: Verifying flashCacheMode on cell: dummy01celadm01  
 2015-05-12 15:01:36  
 STEP 8: Completed sucessfully on cell: dummy01celadm01  
 Flash Cache mode is now WriteBack  
 2015-05-12 15:01:39  
 Skipping STEP 9: Waiting for grid disks to sync not required.  
 2015-05-12 15:01:39  
 STEP 0: Checking gridisk status on cell: dummy01celadm02  
 2015-05-12 15:01:41  
 STEP 0 completed successfully on cell: dummy01celadm02  
 2015-05-12 15:01:44  
 STEP 1: Dropping flashcache on cell: dummy01celadm02  
 2015-05-12 15:02:19  
 STEP 1: Completed sucessfully on cell: dummy01celadm02  
 2015-05-12 15:02:22  
 Skipping STEP 2: Inactivating grid disks not required.  
 2015-05-12 15:02:22  
 Skipping STEP 3: Shutdown of cellsrv not required.  
 2015-05-12 15:02:22  
 STEP 4: Set the flashCachMode on cell: dummy01celadm02  
 2015-05-12 15:02:22  
 STEP 4: Setting flashCacheMode to WriteBack  
 2015-05-12 15:02:23  
 STEP 4: Completed successfully on cell: dummy01celadm02  
 2015-05-12 15:02:26  
 Skipping STEP 5: Restart of cellsrv not required.  
 2015-05-12 15:02:26  
 Skipping STEP 6: Acativating grid disks not required.  
 2015-05-12 15:02:26  
 STEP 7: Creating flashcache on cell: dummy01celadm02  
 2015-05-12 15:03:21  
 STEP 7: Completed sucessfully on cell: dummy01celadm02  
 2015-05-12 15:03:24  
 STEP 8: Verifying flashCacheMode on cell: dummy01celadm02  
 2015-05-12 15:03:25  
 STEP 8: Completed sucessfully on cell: dummy01celadm02  
 Flash Cache mode is now WriteBack  
 2015-05-12 15:03:28  
 Skipping STEP 9: Waiting for grid disks to sync not required.  
 2015-05-12 15:03:28  
 STEP 0: Checking gridisk status on cell: dummy01celadm03  
 2015-05-12 15:03:29  
 STEP 0 completed successfully on cell: dummy01celadm03  
 2015-05-12 15:03:32  
 STEP 1: Dropping flashcache on cell: dummy01celadm03  
 2015-05-12 15:04:07  
 STEP 1: Completed sucessfully on cell: dummy01celadm03  
 2015-05-12 15:04:10  
 Skipping STEP 2: Inactivating grid disks not required.  
 2015-05-12 15:04:10  
 Skipping STEP 3: Shutdown of cellsrv not required.  
 2015-05-12 15:04:10  
 STEP 4: Set the flashCachMode on cell: dummy01celadm03  
 2015-05-12 15:04:10  
 STEP 4: Setting flashCacheMode to WriteBack  
 2015-05-12 15:04:10  
 STEP 4: Completed successfully on cell: dummy01celadm03  
 2015-05-12 15:04:13  
 Skipping STEP 5: Restart of cellsrv not required.  
 2015-05-12 15:04:13  
 Skipping STEP 6: Acativating grid disks not required.  
 2015-05-12 15:04:13  
 STEP 7: Creating flashcache on cell: dummy01celadm03  
 2015-05-12 15:05:09  
 STEP 7: Completed sucessfully on cell: dummy01celadm03  
 2015-05-12 15:05:12  
 STEP 8: Verifying flashCacheMode on cell: dummy01celadm03  
 2015-05-12 15:05:12  
 STEP 8: Completed sucessfully on cell: dummy01celadm03  
 Flash Cache mode is now WriteBack  
 2015-05-12 15:05:15  
 Skipping STEP 9: Waiting for grid disks to sync not required.  
 2015-05-12 15:05:15  
 STEP 0: Checking gridisk status on cell: dummy01celadm04  
 2015-05-12 15:05:17  
 STEP 0 completed successfully on cell: dummy01celadm04  
 2015-05-12 15:05:20  
 STEP 1: Dropping flashcache on cell: dummy01celadm04  
 2015-05-12 15:05:53  
 STEP 1: Completed sucessfully on cell: dummy01celadm04  
 2015-05-12 15:05:56  
 Skipping STEP 2: Inactivating grid disks not required.  
 2015-05-12 15:05:56  
 Skipping STEP 3: Shutdown of cellsrv not required.  
 2015-05-12 15:05:56  
 STEP 4: Set the flashCachMode on cell: dummy01celadm04  
 2015-05-12 15:05:56  
 STEP 4: Setting flashCacheMode to WriteBack  
 2015-05-12 15:06:01  
 STEP 4: Completed successfully on cell: dummy01celadm04  
 2015-05-12 15:06:04  
 Skipping STEP 5: Restart of cellsrv not required.  
 2015-05-12 15:06:04  
 Skipping STEP 6: Acativating grid disks not required.  
 2015-05-12 15:06:04  
 STEP 7: Creating flashcache on cell: dummy01celadm04  
 2015-05-12 15:06:47  
 STEP 7: Completed sucessfully on cell: dummy01celadm04  
 2015-05-12 15:06:50  
 STEP 8: Verifying flashCacheMode on cell: dummy01celadm04  
 2015-05-12 15:06:51  
 STEP 8: Completed sucessfully on cell: dummy01celadm04  
 Flash Cache mode is now WriteBack  
 2015-05-12 15:06:54  
 Skipping STEP 9: Waiting for grid disks to sync not required.  
 2015-05-12 15:06:54  
 STEP 0: Checking gridisk status on cell: dummy01celadm05  
 2015-05-12 15:06:55  
 STEP 0 completed successfully on cell: dummy01celadm05  
 2015-05-12 15:06:58  
 STEP 1: Dropping flashcache on cell: dummy01celadm05  
 2015-05-12 15:07:40  
 STEP 1: Completed sucessfully on cell: dummy01celadm05  
 2015-05-12 15:07:43  
 Skipping STEP 2: Inactivating grid disks not required.  
 2015-05-12 15:07:43  
 Skipping STEP 3: Shutdown of cellsrv not required.  
 2015-05-12 15:07:43  
 STEP 4: Set the flashCachMode on cell: dummy01celadm05  
 2015-05-12 15:07:43  
 STEP 4: Setting flashCacheMode to WriteBack  
 2015-05-12 15:07:43  
 STEP 4: Completed successfully on cell: dummy01celadm05  
 2015-05-12 15:07:46  
 Skipping STEP 5: Restart of cellsrv not required.  
 2015-05-12 15:07:46  
 Skipping STEP 6: Acativating grid disks not required.  
 2015-05-12 15:07:46  
 STEP 7: Creating flashcache on cell: dummy01celadm05  
 2015-05-12 15:08:37  
 STEP 7: Completed sucessfully on cell: dummy01celadm05  
 2015-05-12 15:08:40  
 STEP 8: Verifying flashCacheMode on cell: dummy01celadm05  
 2015-05-12 15:08:41  
 STEP 8: Completed sucessfully on cell: dummy01celadm05  
 Flash Cache mode is now WriteBack  
 2015-05-12 15:08:44  
 Skipping STEP 9: Waiting for grid disks to sync not required.  
 2015-05-12 15:08:44  
 STEP 0: Checking gridisk status on cell: dummy01celadm06  
 2015-05-12 15:08:46  
 STEP 0 completed successfully on cell: dummy01celadm06  
 2015-05-12 15:08:49  
 STEP 1: Dropping flashcache on cell: dummy01celadm06  
 2015-05-12 15:09:23  
 STEP 1: Completed sucessfully on cell: dummy01celadm06  
 2015-05-12 15:09:26  
 Skipping STEP 2: Inactivating grid disks not required.  
 2015-05-12 15:09:26  
 Skipping STEP 3: Shutdown of cellsrv not required.  
 2015-05-12 15:09:26  
 STEP 4: Set the flashCachMode on cell: dummy01celadm06  
 2015-05-12 15:09:26  
 STEP 4: Setting flashCacheMode to WriteBack  
 2015-05-12 15:09:30  
 STEP 4: Completed successfully on cell: dummy01celadm06  
 2015-05-12 15:09:33  
 Skipping STEP 5: Restart of cellsrv not required.  
 2015-05-12 15:09:33  
 Skipping STEP 6: Acativating grid disks not required.  
 2015-05-12 15:09:33  
 STEP 7: Creating flashcache on cell: dummy01celadm06  
 2015-05-12 15:10:19  
 STEP 7: Completed sucessfully on cell: dummy01celadm06  
 2015-05-12 15:10:22  
 STEP 8: Verifying flashCacheMode on cell: dummy01celadm06  
 2015-05-12 15:10:23  
 STEP 8: Completed sucessfully on cell: dummy01celadm06  
 Flash Cache mode is now WriteBack  
 2015-05-12 15:10:26  
 Skipping STEP 9: Waiting for grid disks to sync not required.  
 2015-05-12 15:10:26  
 STEP 0: Checking gridisk status on cell: dummy01celadm07  
 2015-05-12 15:10:28  
 STEP 0 completed successfully on cell: dummy01celadm07  
 2015-05-12 15:10:31  
 STEP 1: Dropping flashcache on cell: dummy01celadm07  
 2015-05-12 15:11:04  
 STEP 1: Completed sucessfully on cell: dummy01celadm07  
 2015-05-12 15:11:07  
 Skipping STEP 2: Inactivating grid disks not required.  
 2015-05-12 15:11:07  
 Skipping STEP 3: Shutdown of cellsrv not required.  
 2015-05-12 15:11:07  
 STEP 4: Set the flashCachMode on cell: dummy01celadm07  
 2015-05-12 15:11:07  
 STEP 4: Setting flashCacheMode to WriteBack  
 2015-05-12 15:11:13  
 STEP 4: Completed successfully on cell: dummy01celadm07  
 2015-05-12 15:11:16  
 Skipping STEP 5: Restart of cellsrv not required.  
 2015-05-12 15:11:16  
 Skipping STEP 6: Acativating grid disks not required.  
 2015-05-12 15:11:16  
 STEP 7: Creating flashcache on cell: dummy01celadm07  
 2015-05-12 15:12:02  
 STEP 7: Completed sucessfully on cell: dummy01celadm07  
 2015-05-12 15:12:05  
 STEP 8: Verifying flashCacheMode on cell: dummy01celadm07  
 2015-05-12 15:12:06  
 STEP 8: Completed sucessfully on cell: dummy01celadm07  
 Flash Cache mode is now WriteBack  
 2015-05-12 15:12:09  
 Skipping STEP 9: Waiting for grid disks to sync not required.  
 2015-05-12 15:12:09  
 Validating inventory for griddisks  
 2015-05-12 15:12:11  
 Validation of griddisk:             [PASSED]  
 2015-05-12 15:12:11  
 Validating inventory for flashdisks  
 2015-05-12 15:12:13  
 Validation of flashdisk:             [PASSED]  
 2015-05-12 15:12:13  
 Validating inventory for flashsize  
 2015-05-12 15:12:14  
 Validation of flashsize:             [PASSED]  
 2015-05-12 15:12:14  
 Setting flash cache to WriteBack completed successfully.  

dcli -g ~/cell_group -l root cellcli -e "list cell attributes flashcachemode"